Name | NOTE |
DC+/DC- | DC voltage input (DC 24V~DC 84V) |
U,V,W | Motor Phase Line |
Hu,Hv,Hw | Hall signal |
VCC | Hall Power + |
SV | External speed regulation. suspended when using internal speed regulation. |
F/R | Direction, suspended or high at normal times positive turn, low level reverse. |
EN | Control signal enable high level stop, low level run |
BRK | Brake, low power normally for normal operation, high level shutdown |
ALARM | Alarm signal output |
Electrical Specifications | |||
Projects | Minimum value | Typical values | Maximum value |
Input voltage | 24 | 48 | 60 |
Output current | - | 6 |
35
|
Apply Motor Speed (rpm)
|
- | - | 20000 |
Hall Signal Voltage (V)
|
4.5 | 5 | 5.5 |
Hall Drive Current (mA)
|
- | 20 | - |
External governor (KΩ)
|
- | 10 | - |
Over-current protection function | Overcurrent protection occurs when the current exceeds the operating current setting value and lasts a set time | ||
Overpressure | An overvoltage protection occurs when the voltage exceeds 30 V | ||
undervoltage | undervoltage protection when voltage is below 10 V | ||
Hall anomaly | Hall signal anomaly | ||
We can also customize products according to customer requirements. |
Name | Note |
DC+/DC
|
DC voltage input (DC 10V~DC 24V)
|
U,V,W
|
Motor Phase Line
|
Hu,Hv,Hw
|
Hall signal
|
VCC
|
Hall Power +
|
SV
|
External speed regulation. suspended when using internal speed regulation
|
F/R |
Direction, suspended or high at normal times positive turn, low level reverse
|
EN
|
Control signal enable high level stop, low level run
|
BRK
|
Brake, low power normally for normal operation, high level shutdown
|
ALARM
|
Alarm signal output
|
Signal
|
Termina
|
Content
|
Power supply Input |
DC+
|
DC power input positive. (Voltage range DC24~60 V)
|
DC-
|
DC power input negative electrode
|
|
Motor
Hall
|
W |
DC brushless motor W phase.
|
V |
DC brushless motor V phase.
|
|
U |
DC brushless motor U phase.
|
|
Signal
Connection |
REF-
|
dc brushless motor hall signal ground wire.
|
HW |
Hall Signal HW. for DC Brushless Motor
|
|
HV
|
Hall Signal HV. for DC Brushless Motor
|
|
HU | Hall Signal HU. for DC Brushless Motor | |
REF+
|
dc brushless motor hall signal power cord.
|
|
Control
Signal
|
SV
|
1 external speed regulating potentiometer ;2 external analog signal speed
regulating input ;3 PWM speed regulating signal input.
|
COM
|
common port (0 V reference level).
|
|
F/R
|
When the F/R end is disconnected from the COM end or when the high level input is
|
|
EN
|
The motor stops slowly when the EN and COM ends are disconnected or high level input, and the motor runs when short connection or low level input. | |
BRK
|
BRK end and COM end disconnect or high level input timing brake stop, short
connection or low level input when motor running.
|
|
Output
signal
|
SPEED
|
corresponding to the running speed of the motor and output the corresponding pulse The formula is: N(rm)=(F/P)x60/3 F:output pulse frequency;Hz:P: motor pole logarithm:N: motor speed 2ms Example:Motor 4 poles F=sec/2msF=500Hz N(rm)=(500/4)x60/3=2500 |
ALM
|
Motor or drive control fault signal output signal, normal 5 V, when failure level
is 0 V..
|
Alarm indication
|
State description
|
Countermeasures
|
Red light flashes 2 times
|
Overpressure alarm
|
alarmCheck voltage
|
Red light flashes 3 times
|
Overflow Alarm for Power Tube
|
Determine whether the selection is correct
|
Red light flashes 4 times
|
Over-current alarm
|
Check P-sv setting, proofread motor parameters. or increase the acceleration time.
|
Red light flashes 5 times
|
undervoltage alarm
|
Check the supply voltage and check whether the supply power meets the condition of 1.5 times greater than the motor power
|
Red light flashes 6 times
|
Hall alarm
|
Please check to see if the motor wiring is secure.
|
Red light
flashes 7 times |
Stopping alarm
|
Make sure the motor load is too large
|
Red light
flashes 8 times
|
More than two alarms
|
Hall and shutoff alarm as a common condition. Adjust the P-sv to the maximum when the motor can not speed.
|
1. How can I use the driver for the first time?
A: After correctly connecting the power line, motor line, and Hall line, the external potentiometer slowly accelerates, and the motor rotates correctly, and then test the enable, direction and other functions in turn. If you are unfamiliar with this product, you should test it for the first time before installing it for actual use.
2. What is the impact of reverse power connection?
A: Will burn the drive immediately.
3. What is the highest voltage of the upper control signal V?
A: The maximum voltage of the speed control signal is 5V, exceeding this voltage will cause the drive to burn.
4. After the driver has been working for a long time, the housing is relatively hot, is it normal?
A: Normally, under normal temperature, working the shell for a long time to 90 degrees will not affect the performance.
5. The power indicator is on, but the motor does not rotate and shakes. What is the reason?
A:It may be that there is an error between the phase line and the Hall line. Please follow the motor manual and reconnect the power to test.
6. Can I adjust the speed of my motor to 6000 with this driver?
A:The maximum speed of the brushless motor is determined by the parameters of the motor itself, and the driver can control the motor speed from 0 to the highest speed.
7. I already have a motor on my hand. How do I connect it after purchasing this driver?
A:You must first determine the definition of the phase line and Hall line of the motor on your hand before wiring. If you are not sure, you need to ask the motor manufacturer. Incorrect wiring will cause damage to the drive.
8. Can I add some functions to this drive or develop new products?
A: Yes, please contact our company.