Customization: | Available |
---|---|
Task: | Adjust |
Structure: | Combination |
Still deciding? Get samples of US$ 15.99/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
BL2406 | |
Name | NOTE |
DC+/DC- | DC voltage input (DC 24V~DC 84V) |
U,V,W | Motor Phase Line |
Hu,Hv,Hw | Hall signal |
VCC | Hall Power + |
SV | External speed regulation. suspended when using internal speed regulation. |
F/R | Direction, suspended or high at normal times positive turn, low level reverse. |
EN | Control signal enable high level stop, low level run |
BRK | Brake, low power normally for normal operation, high level shutdown |
ALARM | Alarm signal output |
Electrical Specifications | ||||
Projects | Minimum value | Typical values | Maximum value | Unit |
Input voltage | 12 | 12 | 24 | VDC |
Output current | 3 | 6 | 8 | A |
undervoltage protection | 10 | VDC | ||
Overpressure protection | 30 | VDC | ||
Speed control | 150 | 3000 | 30000 | Rpm |
Weight | 0.28kg | |||
Size |
60*45*33 Unit MM
|
|||
Control mode | Square waves | |||
Speed regulation mode |
0-5 VDC analog input,
0-100% PWM input (PWM frequency range :[1 Kz-20KHz)
|
|||
Over-current protection function | Overcurrent protection occurs when the current exceeds the operating current setting value and lasts a set time | |||
Overpressure | An overvoltage protection occurs when the voltage exceeds 30 V | |||
undervoltage | undervoltage protection when voltage is below 10 V | |||
Hall anomaly | Hall signal anomaly | |||
We can also customize products according to customer requirements. |
Name | Note |
DC+/DC
|
DC voltage input (DC 10V~DC 24V)
|
U,V,W
|
Motor Phase Line
|
Hu,Hv,Hw
|
Hall signal
|
VCC
|
Hall Power +
|
SV
|
External speed regulation. suspended when using internal speed regulation
|
F/R |
Direction, suspended or high at normal times positive turn, low level reverse
|
EN
|
Control signal enable high level stop, low level run
|
BRK
|
Brake, low power normally for normal operation, high level shutdown
|
ALARM
|
Alarm signal output
|
1. How can I use the driver for the first time?
A: After correctly connecting the power line, motor line, and Hall line, the external potentiometer slowly accelerates, and the motor rotates correctly, and then test the enable, direction and other functions in turn. If you are unfamiliar with this product, you should test it for the first time before installing it for actual use.
2. What is the impact of reverse power connection?
A: Will burn the drive immediately.
3. What is the highest voltage of the upper control signal V?
A: The maximum voltage of the speed control signal is 5V, exceeding this voltage will cause the drive to burn.
4. After the driver has been working for a long time, the housing is relatively hot, is it normal?
A: Normally, under normal temperature, working the shell for a long time to 90 degrees will not affect the performance.
5. The power indicator is on, but the motor does not rotate and shakes. What is the reason?
A:It may be that there is an error between the phase line and the Hall line. Please follow the motor manual and reconnect the power to test.
6. Can I adjust the speed of my motor to 6000 with this driver?
A:The maximum speed of the brushless motor is determined by the parameters of the motor itself, and the driver can control the motor speed from 0 to the highest speed.
7. I already have a motor on my hand. How do I connect it after purchasing this driver?
A:You must first determine the definition of the phase line and Hall line of the motor on your hand before wiring. If you are not sure, you need to ask the motor manufacturer. Incorrect wiring will cause damage to the drive.
8. Can I add some functions to this drive or develop new products?
A: Yes, please contact our company.